CODE TITLE
|
PVH
|
VICKERS PRESSURE COMPENSATED/PRESSURE FLOW COMPENSATED OPEN CIRCUIT PISTON PUMP
|
DISPLACEMENT
|
074
|
73,7 CM3/R [4.50 IN3/R]
|
INPUT SHAFT ROTATION
|
R
|
RIGHT-HAND ROTATION (CW) RIGHT SIDE SUCTION PORT, LEFT SIDE PRESSURE PORT
|
FRONT MOUNTING & INPUT SHAFT
|
01
|
4 BOLT C (SAE J744-127-4) WITH 31.8 [1.25] DIA STRAIGHT KEYED SHAFT (KEY INCLUDED), 56.0 [2.20] SHAFT EXTENSION
|
MAIN PORTS SIZE & LOCATION
|
AA
|
SIDE PORTS; SUCTION - 2.000 SAE 4-BOLT SPLIT FLANGE PORT STANDARD PRESSURE SERIES (CODE 61) WITH 1/2-13 UNC-2B THREADS; PRESSURE - 1.000 SAE 4-BOLT SPLIT FLANGE PORT STANDARD PRESSURE SERIES (CODE 61) WITH 3/8-16 UNC-2B THREADS
|
DRAIN PORT SIZE & LOCATION
|
1
|
.750-16 UNF-2B SAE O-RING PORT - BOTTOM (TOP PLUGGED)
|
DIAGNOSTIC PRESSURE PORT
|
0
|
NO DIAGNOSTIC PRESSURE PORT
|
CONTROLLER TYPE
|
A
|
PRESSURE COMPENSATOR
|
PRESSURE COMPENSATOR SETTING
|
25
|
246-254 BAR [3568-3684 LBF/IN2]
|
FLOW COMP, IC CONT. / UNLOAD VLV STANDBY
|
00
|
NO FLOW COMPENSATION SETTING OR UNLOAD VALVE STANDBY
|
TORQUE SENSING / OTHER COMPENSATION
|
00
|
NO TORQUE SENSING SETTING OR OTHER COMPENSATION
|
CONTROL SPECIAL FEATURES
|
00
|
NO CONTROL SPECIAL FEATURES
|
MAXIMUM DISPLACEMENT OPTION
|
2
|
ADJUSTABLE MAXIMUM DISPLACEMENT (SET AT MAXIMUM)
|
AUXILIARY MOUNTING & OUTPUT SHAFT
|
00
|
NO AUXILIARY MOUNTING OR OUTPUT SHAFT
|
SHAFT SEALS
|
1
|
SINGLE, ONE-WAY SHAFT SEAL, FLUOROCARBON
|
SPECIAL FEATURES
|
AB
|
Q250 VALVE PLATE
|
PAINT
|
01
|
BLUE PRIMER
|
CUSTOMER &/OR UNIT IDENTIFICATION
|
0
|
NONE - MARK ASSEMBLY NUMBER, COMPLETE MODEL CODE AND BUILD DATE CODE ON PLATE
|
DESIGN CODE
|
A
|
FIRST DESIGN
|